B09Y35
High-Sensitivity IEPE Accelerometer
Triaxial
Sensitivity: 500mV/g
Range: ±10g
Frequency (5%): 0.5-5k Hz
Temp Range: -40~120°C
Connector: 1/4-28 4pin
Mount: 10-32/M5 Female
- Fast Lead Time
Overview
The B09Y35 is an impact-resistant, high-sensitivity three-axis IEPE accelerometer built on a piezoelectric ceramic shear sensing element with a wide-bandwidth response and a low-noise circuit optimized for low vibration amplitudes. With 500 mV/g sensitivity and a ±10 g range it is the 500 mV/g, ±10 g member of the family with a 5 kHz bandwidth and the highest shock survivability, for structural work where the sensor may see rough handling or impacts. Typical uses include bridge and building vibration, foundation and ground response, modal testing of large structures and monitoring on machinery subject to impacts.
Shape-memory alloy fasteners and a special structural design extend shock survivability well beyond standard fasteners, to 5,000 g pk, so a dropped or knocked sensor keeps its calibration. The built-in low-impedance circuit gives a good low-frequency response with a ≥ 2 s discharge time constant, and the laser-welded titanium-alloy 19.7 mm cube weighs 37 g, carries an M2.5 thread on each axis for coupling and calibration, and ships with an isolated mounting base as standard.
Why engineers choose the B09Y35
High sensitivity, low noise
500 mV/g output with spectral noise of 3.8 / 1.4 / 0.6 µg/√Hz at 10 / 100 / 1000 Hz and 0.00002 g rms broadband resolution, so the micro-g amplitudes of buildings, bridges and foundations come through clearly above the noise floor.
Survives rough handling
Shape-memory alloy fasteners with a special structural design carry the sensing element through 5,000 g pk shock and 3,000 g rms vibration without damage, far beyond what a high-sensitivity sensor with standard fasteners tolerates on site.
Three axes, one mounting point
Simultaneous X, Y and Z from a single 19.7 mm cube with ≤ 5% transverse sensitivity and a 1/4-28 4-pin connector for one four-core cable. Response from 0.5 Hz to 5 kHz (±5%) with resonance ≥ 32 kHz, M5 stud mount (10-32 optional) and the H02C10 isolated cube base included.
Typical applications
-
Bridge, building and civil structural measurements -
Floor, foundation and ground vibration -
Modal testing of large structures -
Field monitoring where sensors see impacts or rough handling -
Low-level machinery and environmental vibration -
General low-amplitude triaxial vibration measurement
What’s in the box
-
B09Y35 triaxial accelerometer -
Product calibration certificate -
20.7 mm cube isolated mounting base H02C10 -
Mounting screw
Options & accessories
-
TEDS (IEEE 1451.4) for plug-and-play sensor ID – order model 20935Y
-
Optional version: B09Y35-E with 10-32 mounting thread -
Recommended cable K06BB72 (1/4-28 4-pin) – build yours in the Cable Builder
-
Spare isolated mounting base H02C10
Key specifications
Other models in the BXXY35 / Y36 family
Same shear sensing element, high-sensitivity low-noise IEPE circuit, shape-memory alloy fasteners, 19.7 mm cube titanium housing, connector and mounting across the family. Y35 models have a 5 kHz bandwidth, Y36 models 8 kHz. Choose the sensitivity, range and bandwidth that fit your structure.
| Model | Sensitivity | Range | Frequency (±5%) | Noise @ 100 Hz | Vibration · shock limit |
|---|---|---|---|---|---|
| B09Y35This model | 500 mV/g | ±10 g | 0.5 – 5k Hz | 1.4 µg/√Hz | 3,000 g rms · 5,000 g pk |
| B09Y36 | 500 mV/g | ±10 g | 0.5 – 8k Hz | 1.4 µg/√Hz | 3,000 g rms · 5,000 g pk |
| B10Y35 | 1,000 mV/g | ±5 g | 0.5 – 5k Hz | 1.6 µg/√Hz | 400 g rms · 1,000 g pk |
| B10Y36 | 1,000 mV/g | ±5 g | 0.5 – 8k Hz | 1.6 µg/√Hz | 400 g rms · 1,000 g pk |
| Sensitivity (mV/g) | 500 |
|---|---|
| Range (g) | 10 |
| Broadband Resolution (g rms) | 0.00002 |
| Linearity | 1% |
| Frequency Range [5%] (Hz) | 0.5-5k |
| Min Frequency [5%] (Hz) | 0.5 |
| Max Frequency [5%] (Hz) | 5000 |
| Frequency Range [10%] (Hz) | 0.3-6k |
| Resonant Frequency (kHz) | ≥32 |
| Discharge Time Constant (s) | ≥2 |
| Transverse Sensitivity | ≤5% |
| Excitation Voltage (Vdc) | 20-30 Vdc |
| Constant Current Excitation (mA) | 2-20 mA |
| Output Impedance (Ω) | ≤100 |
| Output Bias Voltage (V) | 8-12 Vdc |
| Max Acceleration (g) | 3000 |
| Max Shock (g) | 5000 |
| Temperature Range (℃) | -40~120 |
| Min Temperature (°C) | -40 |
| Max Temperature (°C) | 120 |
| Sensitivity Temperature Coefficient (%/℃) | 0.15 |
| Sealing | Laser Welding IP68 |
| Housing Material | Titanium Alloy |
| Output Connector | 1/4-28 4pin |
| Mounting | 10-32 Female, M5 Female |
| Weight (grams) | 37 |
| Sensor Type | High-Sensitivity |
| Output Type | IEPE |
| Axis | Triaxial |
| TEDS Optional | Yes |
- Datasheet (PDF) B09Y35
- Manual (PDF) Op. & Installation Guide
- Selection Guide (PDF) Accelerometer Selection Guide
- Popular Cables K06BB72
- Popular Mounting Bases H02C10
- TEDS Model 20935Y